US 6 ML over DRAW
Map
Coordinates:
+40.58559, -102.2092440°35'08" N, 102°12'33" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 6 ML over DRAW |
Structure number: | B-28-C |
Location: | 4.9 MI E OF HOLYOKE |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 11.5 ft. [3.5 m] |
Total length: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 88.9 ft. [27.1 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 2005 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,100 [as of 2011] |
Truck traffic: | 20% of total traffic |
Structural appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 99.7 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
May 2017 | Good | 7 out of 10 | 2100 | 99.7 |
May 2015 | Good | 7 out of 10 | 2100 | 99.7 |
May 2013 | Good | 8 out of 10 | 2100 | 96.7 |
May 2011 | Good | 8 out of 10 | 2200 | 99.7 |
April 2009 | Good | 8 out of 10 | 2200 | 99.7 |
June 2007 | Good | 8 out of 10 | 2200 | 99.7 |
June 2005 | Good | 9 out of 10 | 2245 | 99.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 206 | 176 | 30 | 0 | 0 |