Share:

123rd Place over Local Drainage

Map

Coordinates:
+39.92414, -105.05128
39°55'27" N, 105°03'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:123rd Place over Local Drainage
Structure number:BFD-123RD-WOLFF
Location:North of Wolff Drive
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:7.9 ft. [2.4 m]
Total length:34.5 ft. [10.5 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:55.1 ft. [16.8 m]
Owner:City or Municipal Highway Agency [04]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,835 [as of 2016]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:96.8

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
January 2017Good7 out of 10183596.8
January 2015Good7 out of 10183296.8
January 2013Good7 out of 10183296.8
December 2010Good7 out of 10184497.0
December 2008Good7 out of 10184497.0
December 2006Good7 out of 10196797.0
December 2004Good7 out of 10196796.8
November 2002Good7 out of 10196796.8
February 2000Good7 out of 1050097.0
April 1999Good9 out of 1050097.0
April 1998Good9 out of 1050097.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.2202101000
Wearing Surfacessq. ft.1,3111,311000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.6969000
Steel Protective Coatingsq. ft.69490020