Share:

26TH STREET over FOUNTAIN CREEK

Map

Coordinates:
+38.84618, -104.86610
38°50'46" N, 104°51'58" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:26TH STREET over FOUNTAIN CREEK
Structure number:CSG-E.11-09.54
Location:JUST N OF US 24
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:29.2 ft. [8.9 m]
Total length:77.4 ft. [23.6 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:38.1 ft. [11.6 m]
Owner:City or Municipal Highway Agency [04]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,240 [as of 2013]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:79.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2016FairSatisfactorySatisfactorySatisfactory424079.5
May 2014FairSatisfactorySatisfactorySatisfactory424079.5
May 2012FairSatisfactoryGoodSatisfactory440979.5
May 2010FairSatisfactoryGoodSatisfactory440979.5
February 2008FairSatisfactoryGoodFair470168.3
April 2006FairSatisfactoryGoodFair470168.3
May 2004FairGoodGoodSatisfactory470179.5
April 2002FairGoodSatisfactoryGood474679.7
June 2000GoodGoodGoodGood474679.4
October 1999GoodGoodGoodGood474679.4
October 1998GoodGoodGoodGood474679.4
October 1996FairGoodSatisfactoryGood369879.6
July 1994FairGoodSatisfactoryGood369879.7
October 1992FairGoodSatisfactoryGood369879.7
August 1990FairGoodSatisfactoryGood329879.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.3102892010
Deck
Reinforced Concrete Decksq. ft.2,9452,43551000
Wearing Surfacessq. ft.2,9452,79814700
Substructure
Reinforced Concrete Pier Walllinear ft.72621000
Reinforced Concrete Abutmentlinear ft.76661000
Reinforced Concrete Pier Caplinear ft.72581400
Joints
Open Jointlinear ft.7676000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.155155000
Steel Protective Coatingsq. ft.155155000