Share:

FLYING W RANCH RD over DOUGLAS CREEK

Map

Coordinates:
+38.92688, -104.86671
38°55'37" N, 104°52'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FLYING W RANCH RD over DOUGLAS CREEK
Structure number:CSG-E.12-15.07
Location:.25 M SW OF CENTENNIAL BL
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:12.1 ft. [3.7 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:82.0 ft. [25.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1984
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: March 2014

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:4,478 [as of 2013]
Truck traffic:2% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:97.6

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
March 2014Good7 out of 10447897.6
March 2010Good7 out of 10602196.4
April 2006Good7 out of 10460696.6
April 2002Good7 out of 10532998.8
May 2000Good7 out of 10532995.5
September 1999Good7 out of 10532998.5
September 1998Good7 out of 10532998.5
October 1996Good7 out of 10192783.3
August 1994Good7 out of 10192794.4
September 1992Good7 out of 10192783.3
June 1990Good7 out of 10162100.0