Share:

SAINT ELMO AVE over CHEYENNE CREEK

Map

Coordinates:
+38.80828, -104.82528
38°48'30" N, 104°49'31" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SAINT ELMO AVE over CHEYENNE CREEK
Structure number:CSG-G.42-06.97
Location:.2 MI E OF CASCADE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:20.0 ft. [6.1 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:29.2 ft. [8.9 m]
Deck width edge-to-edge:44.3 ft. [13.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1959
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,186 [as of 2013]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:42.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2016FairGoodFairSatisfactory218642.2
April 2014FairGoodFairGood218669.6
April 2012FairGoodFairGood876156.3
April 2010FairGoodFairGood876156.3
February 2008FairVery GoodFairGood264469.5
May 2006FairVery GoodFairGood264469.5
May 2004PoorPoorFairGood264474.4
April 2002FairSatisfactoryGoodGood246188.6
June 2000FairFairFairGood246181.5
September 1999FairFairSatisfactoryGood246192.5
September 1998FairFairSatisfactoryGood246192.5
October 1996FairSatisfactoryGoodGood108694.7
July 1994FairSatisfactoryGoodGood108696.9
October 1992GoodGoodGoodGood108696.9
August 1990GoodGoodGoodGood50097.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5294765300
Steel Protective Coatingsq. ft.5294760053
Deck
Reinforced Concrete Decksq. ft.1,01791510200
Wearing Surfacessq. ft.1,0171,017000
Substructure
Reinforced Concrete Abutmentlinear ft.88493900
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4646000
Steel Protective Coatingsq. ft.4646000
Reinforced Concrete Bridge Raillinear ft.4646000