Share:

NEVADA AVE SB over CS&E RR, VAN BUREN CK

Map

Coordinates:
+38.87057, -104.81982
38°52'14" N, 104°49'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NEVADA AVE SB over CS&E RR, VAN BUREN CK
Structure number:CSG-G.60-11.15S
Location:.2 MI S OF FILLMORE ST
Purpose:Carries highway and pedestrian walkway over railroad and waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:42.7 ft. [13.0 m]
Total length:165.0 ft. [50.3 m]
Roadway width between curbs:30.2 ft. [9.2 m]
Deck width edge-to-edge:38.7 ft. [11.8 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:17°
Owner:City or Municipal Highway Agency [04]
Year built:1949
Year reconstructed:2013
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:13,168 [as of 2013]
Truck traffic:4% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:76.4

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2016GoodVery GoodGoodGood1316876.4
March 2014GoodVery GoodGoodGood1316876.4
March 2012PoorSeriousFairFair847258.9
March 2010FairFairFairFair847264.8
April 2008FairFairFairFair847264.8

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,3211,315600
Steel Protective Coatingsq. ft.1,3211,315006
Deck
Reinforced Concrete Decksq. ft.6,4066,406000
Wearing Surfacessq. ft.6,4066,406000
Substructure
Reinforced Concrete Columneach98100
Reinforced Concrete Abutmentlinear ft.81711000
Reinforced Concrete Pier Caplinear ft.122122000
Joints
Pourable Jointlinear ft.6464000
Compression Jointlinear ft.122122000
Bearings
Movable Bearingeach3224800
Fixed Bearingeach3232000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.330330000