Share:

AUSTIN BLUFFS PKWY over TEMPLETON GAP BASIN

Map

Coordinates:
+38.88919, -104.78254
38°53'21" N, 104°46'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:AUSTIN BLUFFS PKWY over TEMPLETON GAP BASIN
Structure number:CSG-J.00-12.48
Location:0.8 MI W OF ACADEMY BLVD
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:16.4 ft. [5.0 m]
Total length:34.5 ft. [10.5 m]
Roadway width between curbs:90.6 ft. [27.6 m]
Deck width edge-to-edge:222.1 ft. [67.7 m]
Skew angle:32°
Owner:City or Municipal Highway Agency [04]
Year built:1976
Year reconstructed:2014
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:23,207 [as of 2013]
Truck traffic:5% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:94.8
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
May 201694.8Good7 out of 10-23207
May 201494.8Good7 out of 10-23207
May 201293.5Good7 out of 10-37011
May 201093.5Good7 out of 10-37011
March 200893.5Good7 out of 10-37011
April 200693.1Good7 out of 10-42110
May 200493.1Good7 out of 10-42110
April 200287.9Good7 out of 10-38923
May 200091.5Good7 out of 10-38923
October 199991.5Good7 out of 10-38923
October 199891.5Good7 out of 10-38923
November 199676.6Good7 out of 10-31472
June 199476.3Good7 out of 10-31472
October 199276.3Good7 out of 10-31472
July 199093.2Good7 out of 10-25656