Facts

Name:ACADEMY BLVD over TEMPLETON GAP BASIN
Structure number:CSG-J.75-13.04
Location:0.6 MI N. OF AUSTIN BLUFF
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:10.2 ft. [3.1 m]
Total length:21.3 ft. [6.5 m]
Roadway width between curbs:98.4 ft. [30.0 m]
Deck width edge-to-edge:117.1 ft. [35.7 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:46,114 [as of 2013]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:80.0
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
May 201680.0Fair6 out of 10-46114
May 201482.0Fair6 out of 10-46114
May 201282.0Good7 out of 10-41706
May 201082.0Good7 out of 10-41706
March 200882.0Good7 out of 10-41706