Share:

BIJOU STREET over SPRING CREEK

Map

Coordinates:
+38.83575, -104.76360
38°50'09" N, 104°45'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BIJOU STREET over SPRING CREEK
Structure number:CSG-J.80-08.83
Location:0.4 MI W OF ACADEMY BLVD.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:7.9 ft. [2.4 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:49.5 ft. [15.1 m]
Deck width edge-to-edge:92.9 ft. [28.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,729 [as of 2013]
Truck traffic:4% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:80.9
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2016Fair5 out of 10772980.9
May 2014Fair5 out of 10772973.0
May 2012Fair5 out of 10872472.8
May 2010Fair5 out of 10872472.8
March 2008Fair5 out of 10758273.0
April 2006Fair5 out of 10758273.0
May 2004Fair6 out of 10758281.1
April 2002Fair5 out of 10920770.4
June 2000Fair6 out of 10920781.0
October 1999Fair6 out of 10920781.0
October 1998Fair6 out of 10920781.0
November 1996Fair5 out of 10595370.2
July 1994Fair5 out of 10595370.4
October 1992Fair5 out of 10595370.4
July 1990Fair5 out of 10570066.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.27949200300