Share:

ACADEMY BLVD over LOCAL DRAINAGE

Map

Coordinates:
+38.88480, -104.75674
38°53'05" N, 104°45'24" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ACADEMY BLVD over LOCAL DRAINAGE
Structure number:CSG-K.08-12.22
Location:0.4 MI S OF AUSTIN BLUFFS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:9.5 ft. [2.9 m]
Total length:20.3 ft. [6.2 m]
Roadway width between curbs:103.0 ft. [31.4 m]
Deck width edge-to-edge:136.2 ft. [41.5 m]
Skew angle:34°
Owner:City or Municipal Highway Agency [04]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:52,993 [as of 2013]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:84.6
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2016Fair6 out of 105299384.6
May 2014Fair6 out of 105299384.6
May 2012Fair6 out of 104918485.5
May 2010Fair6 out of 104918485.5
March 2008Good7 out of 104918485.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.324032220
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4141000
Steel Protective Coatingsq. ft.4141000