Share:

SPRINGNITE DRIVE over MAIN STREAM

Map

Coordinates:
+38.78586, -104.75190
38°47'09" N, 104°45'07" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SPRINGNITE DRIVE over MAIN STREAM
Structure number:CSG-K.47-05.33
Location:N OF DRENNAN/E ACADEMY
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:12.1 ft. [3.7 m]
Total length:24.9 ft. [7.6 m]
Roadway width between curbs:36.1 ft. [11.0 m]
Deck width edge-to-edge:46.9 ft. [14.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1982
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,325 [as of 2013]
Truck traffic:2% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:63.8

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2016Fair5 out of 10132563.8
May 2014Fair5 out of 10132585.9
May 2010Fair6 out of 10155496.9
April 2006Fair6 out of 10182096.8
April 2002Good7 out of 10159096.9
June 2000Good7 out of 10159096.9
October 1999Good7 out of 10159096.9
October 1998Good7 out of 10159096.9
October 1996Good7 out of 10108496.9
July 1994Good7 out of 10108496.9
October 1992Good7 out of 10108496.9
July 1990Good7 out of 1092996.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.9400940
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.5050000
Steel Protective Coatingsq. ft.5050000