Share:

PALMER PARK BLVD over WEST FORK SAND CREEK

Map

Coordinates:
+38.85418, -104.73663
38°51'15" N, 104°44'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PALMER PARK BLVD over WEST FORK SAND CREEK
Structure number:CSG-L.08-10.08
Location:0.8 MI E OF MURRAY BLVD.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:9.8 ft. [3.0 m]
Total length:20.3 ft. [6.2 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:68.9 ft. [21.0 m]
Skew angle:24°
Owner:City or Municipal Highway Agency [04]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,117 [as of 2013]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:95.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
April 2016Fair6 out of 101011795.0
April 2014Fair6 out of 101011795.0
December 2012Fair6 out of 101337294.7
June 2010Fair6 out of 101337294.7
April 2006Good7 out of 101096196.0
April 2002Fair6 out of 10922196.6
June 2000Good7 out of 10922196.1
October 1999Good7 out of 10922196.1
October 1998Good7 out of 10922196.1
November 1996Fair6 out of 10900495.1
July 1994Fair6 out of 10900481.2
October 1992Fair6 out of 10900481.2
July 1990Fair6 out of 10794196.4

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.15110821220
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4136500
Steel Protective Coatingsq. ft.4136005