Share:

GALLEY ROAD over SAND CREEK

Map 

Coordinates:
+38.84644, -104.72444
38°50'47" N, 104°43'28" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:GALLEY ROAD over SAND CREEK
Structure number:CSG-L.80-09.61
Location:0.25 MI W OF POWERS BLVD.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:76.4 ft. [23.3 m]
Total length:156.2 ft. [47.6 m]
Roadway width between curbs:64.0 ft. [19.5 m]
Deck width edge-to-edge:80.4 ft. [24.5 m]
Skew angle:65°
Owner:City or Municipal Highway Agency [04]
Year built:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,929 [as of 2013]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:66.1 tons [60.1 metric tons]
Inventory rating:39.7 tons [36.1 metric tons]
Sufficiency rating:97.0

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
May 201697.0FairGoodSatisfactorySatisfactory-13929
May 201497.0FairGoodSatisfactoryGood-13929
June 201096.9FairGoodSatisfactoryGood-15285
April 200696.0FairGoodSatisfactoryGood-14247
April 200297.1GoodVery GoodVery GoodVery Good-13622
June 200098.1GoodGoodGoodGood-13622
October 199998.1GoodVery GoodGoodVery Good-13622
October 199898.1GoodVery GoodGoodVery Good-13622
November 199690.7GoodVery GoodVery GoodVery Good-59241
August 199490.1GoodExcellentExcellentExcellent-59241