SH 64 ML over SPRING CREEK
Map
Coordinates:
+40.15705, -108.6833140°09'25" N, 108°40'60" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 64 ML over SPRING CREEK |
Structure number: | D-02-A |
Location: | 9 MI E OF RANGELY |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 38.4 ft. [11.7 m] |
Total length: | 105.6 ft. [32.2 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 27.9 ft. [8.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1949 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,100 [as of 2011] |
Truck traffic: | 17% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 38.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Fair | Fair | Satisfactory | 1100 | 38.4 |
April 2016 | Fair | Fair | Fair | Satisfactory | 1100 | 38.4 |
April 2014 | Fair | Fair | Fair | Satisfactory | 1100 | 38.4 |
May 2012 | Fair | Fair | Fair | Satisfactory | 1200 | 38.4 |
May 2010 | Fair | Fair | Fair | Satisfactory | 1200 | 38.4 |
May 2008 | Fair | Fair | Fair | Satisfactory | 1200 | 38.4 |
June 2006 | Fair | Fair | Satisfactory | Good | 1600 | 48.4 |
May 2004 | Fair | Fair | Satisfactory | Good | 1489 | 53.0 |
April 2002 | Fair | Fair | Satisfactory | Good | 518 | 76.3 |
May 2000 | Fair | Fair | Satisfactory | Good | 504 | 69.0 |
May 1998 | Fair | Fair | Satisfactory | Good | 504 | 69.0 |
March 1996 | Fair | Fair | Satisfactory | Good | 800 | 58.6 |
June 1994 | Fair | Fair | Satisfactory | Good | 800 | 64.9 |
June 1991 | Fair | Fair | Satisfactory | Satisfactory | 580 | 70.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 515 | 0 | 418 | 97 | 0 |
Steel Protective Coating | sq. ft. | 515 | 0 | 0 | 0 | 515 |
Deck |
Reinforced Concrete Deck | sq. ft. | 2,957 | 2,857 | 100 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,957 | 2,957 | 0 | 0 | 0 |
Substructure |
Steel Column | each | 10 | 0 | 9 | 1 | 0 |
Steel Protective Coating | sq. ft. | 10 | 0 | 0 | 0 | 10 |
Reinforced Concrete Abutment | linear ft. | 56 | 56 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 55 | 48 | 5 | 2 | 0 |
Joints |
Open Joint | linear ft. | 56 | 56 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 15 | 0 | 8 | 7 | 0 |
Steel Protective Coating | sq. ft. | 15 | 0 | 0 | 0 | 15 |
Fixed Bearing | each | 15 | 9 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 15 | 15 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 212 | 212 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 212 | 212 | 0 | 0 | 0 |