Share:

PRINCETON AVE over GOLDSMITH GULCH

Map 

Coordinates:
+39.64330, -104.89418
39°38'36" N, 104°53'39" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:PRINCETON AVE over GOLDSMITH GULCH
Structure number:D-11-GG-180A
Location:W OF TAMARAC DRIVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:16.4 ft. [5.0 m]
Total length:33.5 ft. [10.2 m]
Roadway width between curbs:46.3 ft. [14.1 m]
Deck width edge-to-edge:63.3 ft. [19.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,155 [as of 2013]
Truck traffic:2% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:39.9 tons [36.3 metric tons]
Inventory rating:36.0 tons [32.7 metric tons]
Sufficiency rating:96.8

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201696.8Fair6 out of 10-2155
December 201496.8Fair6 out of 10-2155
December 201296.8Fair6 out of 10-2155
December 201096.8Fair6 out of 10-2246
September 200896.8Fair6 out of 10-2246
January 200796.8Good7 out of 10-2058
August 200496.8Good7 out of 10-2058
October 200296.8Good7 out of 10-2058
July 200096.8Good7 out of 10-2204
December 199996.8Good7 out of 10-2204
December 199896.8Good7 out of 10-2204
May 199696.8Good7 out of 10-1817
November 199496.9Good7 out of 10-1817