Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:QUINCY AVE over GOLDSMITH GULCH
Structure number:D-11-GG-190
Location:JUST NE OF TAMARAC STREET
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:12.8 ft. [3.9 m]
Total length:29.9 ft. [9.1 m]
Deck width edge-to-edge:130.9 ft. [39.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Steel [3]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,808 [as of 2013]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:95.9

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
December 2016Fair6 out of 101180895.9
December 2014Fair6 out of 101180895.9
December 2012Fair6 out of 101180895.9
December 2010Fair6 out of 101115296.0
September 2008Fair6 out of 101115296.0
January 2007Fair6 out of 101292195.8
August 2004Good7 out of 101292195.8
October 2002Good7 out of 101292195.8
July 2000Good7 out of 101239595.8
December 1999Good7 out of 101239595.8
December 1998Good7 out of 101239595.8
May 1996Good7 out of 10919196.1
November 1994Good7 out of 10919196.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Steel Culvertlinear ft.242002420
Wearing Surfacessq. ft.1,69601,69600
Steel Protective Coatingsq. ft.242002420