Share:

6 DIFFERENT STREET over WEIR GULCH

Map

Coordinates:
+39.72029, -105.03251
39°43'13" N, 105°01'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:6 DIFFERENT STREET over WEIR GULCH
Structure number:D-17-WG-150
Location:OSCEOLA TO KNOX CT
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:20.7 ft. [6.3 m]
Deck width edge-to-edge:2243.2 ft. [683.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1977
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,855 [as of 2013]
Truck traffic:2% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:65.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
January 2017Fair6 out of 10985565.0
January 2015Fair6 out of 10985565.0
January 2013Fair6 out of 10985568.0
January 2011Fair6 out of 10736668.4
November 2008Fair6 out of 10736668.4
November 2006Fair6 out of 10782065.3
October 2004Fair6 out of 10782065.3
November 2002Fair6 out of 10782062.8
July 2000Fair6 out of 1069264.8
December 1999Fair6 out of 1069264.8
December 1998Fair6 out of 1069264.8
May 1996Fair6 out of 1062264.8
November 1994Fair6 out of 1062273.2

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.4,4863,4436823610
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4242000
Steel Protective Coatingsq. ft.4242000