Share:

UNION AVENUE over BEAR CREEK

Map

Coordinates:
+39.65286, -105.20031
39°39'10" N, 105°12'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:UNION AVENUE over BEAR CREEK
Structure number:D-27-MP-030A
Location:DENVER MT PARK OFFICE
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:38.7 ft. [11.8 m]
Total length:46.9 ft. [14.3 m]
Roadway width between curbs:14.4 ft. [4.4 m]
Deck width edge-to-edge:15.7 ft. [4.8 m]
Skew angle:20°
Owner:City or Municipal Highway Agency [04]
Year built:1999
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Wood or timber [7]
Main span design:Slab [01]
Deck type:Wood or Timber [8]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:89 [as of 2013]
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:89.8 tons [81.6 metric tons]
Inventory rating:89.8 tons [81.6 metric tons]
Sufficiency rating:76.2

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201676.2FairGoodSatisfactorySatisfactory-89
November 201476.2FairGoodSatisfactorySatisfactory-89
November 201276.2FairGoodSatisfactorySatisfactory-89
November 201076.6GoodGoodGoodGood-47
October 200876.6GoodGoodGoodGood-47
November 200676.5GoodGoodGoodGood-60
October 200476.5GoodGoodGoodGood-60
October 200276.5GoodVery GoodVery GoodGood-60
August 200076.3GoodExcellentExcellentGood-64

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.9400940
Steel Protective Coatingsq. ft.10,75310,753000
Steel Floor Beamlinear ft.109109000
Steel Protective Coatingsq. ft.10,75310,753000
Substructure
Masonry Abutmentlinear ft.3331110
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.9489500
Steel Protective Coatingsq. ft.10,75310,753000
Deck
Timber Slabsq. ft.733733000
Wearing Surfacessq. ft.733733000