Share:

SB PENA BLVD over SECOND CREEK TRIB

Map

Coordinates:
+39.83263, -104.77651
39°49'57" N, 104°46'35" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SB PENA BLVD over SECOND CREEK TRIB
Structure number:D-31-PB-310
Location:WEST OF TOWER ROAD
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:143.1 ft. [43.6 m]
Total length:148.3 ft. [45.2 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:42.7 ft. [13.0 m]
Skew angle:
Owner:Other Local Agencies [25]
Year built:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:39,498 [as of 2016]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:96.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2018FairSatisfactoryGoodGood3949896.3
December 2016FairSatisfactoryGoodGood2826697.4
December 2014FairSatisfactoryGoodGood2826697.4
December 2012FairSatisfactoryGoodGood2826695.4
December 2010FairSatisfactoryGoodGood1700696.4
December 2008FairSatisfactoryGoodGood1700696.4
November 2006FairSatisfactoryGoodGood2298095.9
October 2004FairSatisfactoryGoodGood2298095.9
September 2002FairSatisfactoryVery GoodGood2298097.9
August 2000FairSatisfactoryVery GoodGood2265997.9
November 1999GoodGoodVery GoodVery Good2265997.9
November 1998GoodGoodVery GoodVery Good2265997.9
June 1996GoodGoodVery GoodVery Good2344997.8
November 1994GoodVery GoodVery GoodVery Good300099.8
January 1993GoodExcellentExcellentExcellent300097.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.736731500
Concrete Protective Coatingsq. ft.740740000
Deck
Reinforced Concrete Decksq. ft.5,9675,9155200
Prestressed Concrete Top Flangesq. ft.5,8354,3761,45900
Substructure
Reinforced Concrete Abutmentlinear ft.156152400
Concrete Protective Coatingsq. ft.156156000
Joints
Strip Seal Jointlinear ft.78354300
Pourable Jointlinear ft.1561114005
Compression Jointlinear ft.7875300
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.296296000
Steel Protective Coatingsq. ft.296296000