Share:

PENA BLVD over SECOND CREEK

Map 

Coordinates:
+39.83351, -104.73031
39°50'01" N, 104°43'49" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:PENA BLVD over SECOND CREEK
Structure number:D-31-PB-440
Location:JUST EAST OF PICADILLY RD
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:13.8 ft. [4.2 m]
Total length:37.1 ft. [11.3 m]
Deck width edge-to-edge:503.3 ft. [153.4 m]
Skew angle:30°
Owner:City or Municipal Highway Agency [04]
Year built:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2014 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,070 [as of 2013]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:89.8 tons [81.6 metric tons]
Inventory rating:89.8 tons [81.6 metric tons]
Sufficiency rating:83.5

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201483.5Fair6 out of 10-13070
December 201283.5Fair6 out of 10-13070
December 201079.1Fair6 out of 10-51797
December 200879.1Fair6 out of 10-51797
November 200631.5Fair6 out of 10FO63760
October 200431.5Good7 out of 10FO63760
September 200277.7Good7 out of 10-63760
August 200077.9Good7 out of 10-62793
November 199977.9Good7 out of 10-62793
November 199877.9Good7 out of 10-62793
June 199691.5Good7 out of 10-58213
November 199496.8Good8 out of 10-3000
January 199396.8Good8 out of 10-3000