Share:

COUNTY ROAD 4405 over FIRE MOUNTAIN CANAL

Map

Coordinates:
+38.92564, -107.52461
38°55'32" N, 107°31'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD 4405 over FIRE MOUNTAIN CANAL
Structure number:DEL4405D-.1-61
Location:2 Mi NE of SH133/Bowie RD
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:34.5 ft. [10.5 m]
Total length:36.1 ft. [11.0 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Skew angle:50°
Owner:County Highway Agency [02]
Year built:1976
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Gravel [8]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:23 [as of 2013]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:62.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017FairSatisfactorySatisfactoryFair2362.0
October 2015FairSatisfactorySatisfactoryFair2361.0
October 2013FairSatisfactorySatisfactoryFair2361.0
October 2011FairSatisfactorySatisfactorySatisfactory56253.5
October 2009FairSatisfactorySatisfactorySatisfactory1072.2
September 2007FairGoodSatisfactorySatisfactory1072.2
September 2005FairGoodSatisfactorySatisfactory1072.2
December 2003FairGoodSatisfactorySatisfactory1072.2
March 2001FairGoodSatisfactorySatisfactory1571.3
March 1999FairGoodSatisfactorySatisfactory1571.3
March 1997FairGoodSatisfactorySatisfactory1571.3
April 1995FairGoodSatisfactorySatisfactory370.5
March 1993FairGoodSatisfactorySatisfactory370.5
April 1991FairGoodSatisfactorySatisfactory370.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.398003980
Substructure
Reinforced Concrete Abutmentlinear ft.7574100
Reinforced Concrete Pile Cap/Footinglinear ft.1715200
Steel Pier Caplinear ft.7507500
Deck
Corrugated or Orthotropic Decksq. ft.87267220000
Wearing Surfacessq. ft.872087200
Steel Protective Coatingsq. ft.87267220000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.72224820
Steel Protective Coatingsq. ft.72423000