Share:

160TH AVE over I-25

Map

Coordinates:
+39.98657, -104.98840
39°59'12" N, 104°59'18" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:160TH AVE over I-25
Structure number:E-17-ZN
Location:Just N of NWPkwy-470
Purpose:Carries highway over highway
Route classification:Collector (Urban) [17]
Length of largest span:162.1 ft. [49.4 m]
Total length:326.5 ft. [99.5 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:11°
Owner:State Highway Agency [01]
Year built:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:2
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,961 [as of 2008]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:99.8

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017GoodGoodVery GoodGood196199.8
March 2015GoodGoodVery GoodGood196199.8
March 2013GoodGoodVery GoodGood196199.8
March 2011GoodGoodVery GoodGood196199.8
February 2009GoodExcellentExcellentExcellent196199.8
July 2006GoodExcellentExcellentExcellent100098.9
January 2005GoodVery GoodVery GoodVery Good2317100.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2,2862,285100
Deck
Reinforced Concrete Decksq. ft.14,044014,04400
Wearing Surfacessq. ft.13,0649,79403,2664
Substructure
Reinforced Concrete Pier Walllinear ft.2424000
Reinforced Concrete Abutmentlinear ft.88167020
Reinforced Concrete Pier Caplinear ft.4040000
Joints
Strip Seal Jointlinear ft.8808008
Pourable Jointlinear ft.8888000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.653653000
Steel Protective Coatingsq. ft.653653000