Share:

4th Street over Greeley No. 3 Ditch

Map

Coordinates:
+40.43017, -104.71964
40°25'49" N, 104°43'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:4th Street over Greeley No. 3 Ditch
Structure number:GREELEY-0000008
Location:2400 Blk-4th Street
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:25.9 ft. [7.9 m]
Total length:29.9 ft. [9.1 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:56.1 ft. [17.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1970
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Tee beam [04]
Deck type:Other [9]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,142 [as of 2012]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:83.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairFairFairFair1014283.9
April 2016FairFairFairFair1014283.9
April 2014FairFairFairSatisfactory1014283.9
March 2012FairFairFairSatisfactory1014283.9
March 2010FairSatisfactoryFairSatisfactory709385.2
February 2008FairSatisfactoryFairGood709386.0
January 2006GoodGoodGoodVery Good1007197.0
March 2004GoodGoodGoodGood1007197.0
January 2002FairGoodFairGood619286.0
May 1999FairGoodFairGood619286.0
April 1997FairGoodFairGood619286.0
April 1995FairGoodFairGood480886.0
December 1993FairGoodFairGood480886.0
March 1991GoodGoodGoodGood480897.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.4804160640
Deck
Prestressed Concrete Top Flangesq. ft.1,680997615680
Wearing Surfacessq. ft.1,4401,440000
Substructure
Reinforced Concrete Abutmentlinear ft.1122675110
Steel Pileeach50050
Joints
Other Jointlinear ft.210021000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.60501000
Steel Protective Coatingsq. ft.60500010