SH 9 ML over S FK SOUTH PLATTE RVR
Map
Coordinates:
+39.01986, -105.7921239°01'11" N, 105°47'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 9 ML over S FK SOUTH PLATTE RVR |
Structure number: | H-13-E |
Location: | 0.2 MI S. OF HARTSEL |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 9.5 ft. [2.9 m] |
Total length: | 24.6 ft. [7.5 m] |
Roadway width between curbs: | 26.9 ft. [8.2 m] |
Deck width edge-to-edge: | 45.9 ft. [14.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1966 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 640 [as of 2011] |
Truck traffic: | 14% of total traffic |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Culvert condition: | Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 84.7 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
November 2017 | Fair | 6 out of 10 | 640 | 84.7 |
November 2015 | Fair | 6 out of 10 | 640 | 84.7 |
November 2013 | Good | 7 out of 10 | 640 | 86.0 |
December 2011 | Poor | 4 out of 10 | 650 | 56.1 |
November 2009 | Poor | 4 out of 10 | 650 | 56.1 |
October 2007 | Poor | 4 out of 10 | 602 | 56.8 |
November 2005 | Poor | 4 out of 10 | 602 | 56.8 |
November 2003 | Fair | 6 out of 10 | 603 | 93.4 |
October 2001 | Fair | 6 out of 10 | 603 | 86.4 |
November 1999 | Fair | 6 out of 10 | 588 | 86.5 |
October 1997 | Fair | 6 out of 10 | 420 | 88.1 |
November 1995 | Fair | 6 out of 10 | 420 | 88.9 |
October 1993 | Fair | 6 out of 10 | 390 | 89.1 |
October 1992 | Good | 7 out of 10 | 390 | 89.1 |
November 1990 | Good | 7 out of 10 | 290 | 89.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Steel Culvert | linear ft. | 92 | 0 | 92 | 0 | 0 |
Steel Protective Coating | sq. ft. | 92 | 0 | 0 | 0 | 92 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 50 | 50 | 0 | 0 | 0 |