Share:

US 24 WB/PLATTE AV over PETERSON FIELD ROAD

Map

Coordinates:
+38.83955, -104.70155
38°50'22" N, 104°42'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 24 WB/PLATTE AV over PETERSON FIELD ROAD
Structure number:I-18-AT
Location:3/4 MI E OF POWERS
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:41.7 ft. [12.7 m]
Total length:147.6 ft. [45.0 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:16.7 ft. [5.1 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:16,000 [as of 2011]
Truck traffic:7% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:51.9 tons [47.2 metric tons]
Inventory rating:30.9 tons [28.1 metric tons]
Sufficiency rating:93.1

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201693.1FairSatisfactorySatisfactoryGoodFO16000
December 201493.1FairSatisfactorySatisfactoryGoodFO16000
January 201393.1FairSatisfactorySatisfactoryGoodFO16250
December 201092.1FairFairSatisfactoryGoodFO16250
January 200989.1FairFairSatisfactoryGoodFO16250
November 200689.1FairFairSatisfactoryGoodFO14150
October 200489.1FairFairSatisfactoryGoodFO20073
October 200289.1FairFairSatisfactoryGoodFO8398
October 200088.9FairFairSatisfactoryGoodFO7500
December 199886.9FairFairGoodGoodFO7500
December 199689.7FairFairGoodGoodFO3875
December 199491.7FairSatisfactoryGoodGoodFO3875
December 199192.0FairSatisfactoryGoodGoodFO3100

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.720715500
Deck
Reinforced Concrete Decksq. ft.6,1963,90302,2930
Wearing Surfacessq. ft.6,1966,196000
Substructure
Reinforced Concrete Columneach99000
Reinforced Concrete Abutmentlinear ft.8686000
Reinforced Concrete Pier Caplinear ft.108108000
Joints
Pourable Jointlinear ft.7676000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.296296000
Steel Protective Coatingsq. ft.10,75310,753000