SH 96 ML over BIG SANDY CREEK
Map
Coordinates:
+38.43851, -102.5130138°26'19" N, 102°30'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 96 ML over BIG SANDY CREEK |
Structure number: | K-26-A |
Location: | 1.4 MI E OF CHIVINGTON |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 40.0 ft. [12.2 m] |
Total length: | 329.1 ft. [100.3 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 32.2 ft. [9.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1962 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 8 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 420 [as of 2011] |
Truck traffic: | 31% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 87.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Fair | Good | Satisfactory | Fair | 420 | 87.5 |
June 2016 | Fair | Good | Satisfactory | Satisfactory | 420 | 96.5 |
June 2014 | Fair | Good | Satisfactory | Satisfactory | 420 | 96.5 |
June 2012 | Fair | Good | Satisfactory | Satisfactory | 500 | 96.4 |
June 2010 | Fair | Good | Satisfactory | Satisfactory | 500 | 96.4 |
June 2008 | Fair | Good | Satisfactory | Satisfactory | 500 | 96.4 |
April 2006 | Fair | Good | Satisfactory | Satisfactory | 510 | 96.4 |
May 2004 | Fair | Good | Satisfactory | Satisfactory | 589 | 96.3 |
April 2002 | Good | Good | Good | Good | 584 | 93.3 |
June 1998 | Good | Good | Good | Good | 567 | 93.1 |
March 1996 | Good | Good | Good | Good | 380 | 94.4 |
April 1994 | Good | Good | Good | Good | 520 | 93.2 |
April 1991 | Fair | Good | Satisfactory | Good | 550 | 93.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,316 | 1,266 | 50 | 0 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 10,528 | 10,494 | 30 | 4 | 0 |
Wearing Surfaces | sq. ft. | 9,212 | 9,000 | 212 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 175 | 170 | 1 | 4 | 0 |
Reinforced Concrete Abutment | linear ft. | 64 | 64 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 210 | 180 | 20 | 10 | 0 |
Joints |
Pourable Joint | linear ft. | 252 | 252 | 0 | 0 | 0 |
Bearings |
Fixed Bearing | each | 56 | 32 | 24 | 0 | 0 |
Steel Protective Coating | sq. ft. | 56 | 32 | 0 | 0 | 24 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 658 | 634 | 24 | 0 | 0 |
Steel Protective Coating | sq. ft. | 658 | 658 | 0 | 0 | 0 |