Share:

I 25 ML SBND over POPE ARROYO

Map

Coordinates:
+37.85614, -104.82889
37°51'22" N, 104°49'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I 25 ML SBND over POPE ARROYO
Structure number:M-17-AT
Location:16.5 MI N OF WALSENBURG
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:3.6 ft. [1.1 m]
Total length:86.0 ft. [26.2 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,500 [as of 2011]
Truck traffic:18% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:94.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2016FairSatisfactoryGoodGood550094.2
December 2014FairSatisfactoryGoodGood550094.2
December 2012FairSatisfactoryGoodGood615094.2
December 2010FairSatisfactoryGoodGood615094.2
October 2008FairSatisfactoryGoodGood615094.2
December 2006FairSatisfactoryGoodGood760097.6
October 2002FairSatisfactoryGoodGood538596.8
October 1998FairSatisfactoryGoodGood505096.5
November 1996FairSatisfactoryGoodGood425096.6
December 1994FairGoodGoodSatisfactory425095.9
January 1993GoodGoodGoodGood390096.9
November 1990FairGoodGoodSatisfactory352596.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.430428200
Deck
Reinforced Concrete Top Flangesq. ft.3,6123,612000
Wearing Surfacessq. ft.3,3543,354000
Substructure
Steel Columneach106400
Steel Protective Coatingsq. ft.106400
Reinforced Concrete Abutmentlinear ft.8682220
Reinforced Concrete Pier Caplinear ft.6867100
Joints
Other Jointlinear ft.8686000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.172172000
Steel Protective Coatingsq. ft.172172000