Share:

SH 109 ML over RDWY, RR, ARKANSAS RVR

Map

Coordinates:
+37.98786, -103.53182
37°59'16" N, 103°31'55" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SH 109 ML over RDWY, RR, ARKANSAS RVR
Structure number:M-22-AY
Location:LA JUNTA
Purpose:Carries highway overpass over highway, waterway, and railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:87.9 ft. [26.8 m]
Total length:1448.2 ft. [441.4 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:16
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,500 [as of 2011]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:67.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairSatisfactorySatisfactoryFair450067.9
April 2016FairSatisfactorySatisfactoryFair450067.9
April 2014FairSatisfactorySatisfactoryFair450067.9
April 2012FairSatisfactoryGoodFair510067.8
May 2010FairSatisfactoryGoodSatisfactory510079.0
May 2008FairSatisfactoryGoodSatisfactory510079.0
May 2006FairSatisfactoryGoodSatisfactory610078.8
April 2004FairSatisfactoryGoodSatisfactory575078.8
April 2002FairSatisfactoryGoodSatisfactory635878.7
May 2000FairSatisfactoryGoodSatisfactory715078.5
June 1998FairSatisfactoryGoodSatisfactory715078.5
January 1997FairSatisfactoryGoodSatisfactory775078.4
January 1994FairSatisfactoryGoodSatisfactory715078.7
March 1991FairSatisfactoryGoodSatisfactory670076.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.7,0256,92550500
Reinforced Concrete Girder/Beamlinear ft.174174000
Deck
Reinforced Concrete Decksq. ft.52,12826,97822,6502,5000
Wearing Surfacessq. ft.43,44023,44020,00000
Substructure
Steel Columneach1221000
Steel Protective Coatingsq. ft.1220010
Reinforced Concrete Columneach168440
Reinforced Concrete Pier Walllinear ft.186176460
Reinforced Concrete Abutmentlinear ft.1111011000
Reinforced Concrete Pier Caplinear ft.5252111191950
Joints
Pourable Jointlinear ft.5424905200
Compression Jointlinear ft.177177000
Bearings
Elastomeric Bearingeach160160000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.2,8152,815000
Steel Protective Coatingsq. ft.2,8152,815000