County Road 23 over Patent Creek
Map
Coordinates:
+40.44656, -102.4548140°26'48" N, 102°27'17" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | County Road 23 over Patent Creek |
Structure number: | PH23-0.5-2 |
Location: | 0.5 Mi No of Co Rd 2 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 25.6 ft. [7.8 m] |
Total length: | 72.5 ft. [22.1 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 24.0 ft. [7.3 m] |
Skew angle: | 30° |
Owner: | County Highway Agency [02] |
Year built: | 1966 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Gravel [8] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 25 [as of 2012] |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 55.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Satisfactory | Fair | 25 | 55.2 |
December 2015 | Fair | Satisfactory | Satisfactory | Fair | 25 | 58.0 |
December 2013 | Fair | Satisfactory | Good | Fair | 25 | 57.0 |
December 2011 | Fair | Satisfactory | Good | Fair | 25 | 57.0 |
December 2009 | Fair | Satisfactory | Good | Satisfactory | 21 | 67.1 |
December 2007 | Fair | Satisfactory | Good | Good | 21 | 67.1 |
October 2005 | Good | Good | Very Good | Good | 14 | 52.3 |
October 2003 | Good | Good | Very Good | Good | 21 | 65.6 |
March 2001 | Good | Good | Very Good | Good | 21 | 65.3 |
March 2000 | Fair | Satisfactory | Good | Good | 21 | 65.3 |
March 1999 | Fair | Satisfactory | Good | Good | 21 | 65.3 |
March 1998 | Fair | Satisfactory | Good | Good | 21 | 65.3 |
June 1996 | Fair | Satisfactory | Good | Good | 53 | 65.3 |
May 1994 | Good | Good | Very Good | Good | 53 | 50.8 |
March 1992 | Poor | Good | Very Good | Poor | 53 | 40.0 |
May 1990 | Good | Good | Very Good | Good | 19 | 53.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 579 | 0 | 579 | 0 | 0 |
Steel Protective Coating | sq. ft. | 579 | 0 | 0 | 0 | 579 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,730 | 1,451 | 134 | 145 | 0 |
Substructure |
Steel Column | each | 10 | 0 | 10 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10 | 0 | 0 | 0 | 10 |
Reinforced Concrete Abutment | linear ft. | 55 | 0 | 55 | 0 | 0 |
Steel Pier Cap | linear ft. | 55 | 0 | 55 | 0 | 0 |
Steel Protective Coating | sq. ft. | 55 | 0 | 0 | 0 | 55 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 145 | 119 | 26 | 0 | 0 |
Steel Protective Coating | sq. ft. | 145 | 121 | 0 | 0 | 24 |