Share:

CR230/BRNT MILL RD over DRY WASH

Map

Coordinates:
+38.04549, -104.79972
38°02'44" N, 104°47'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR230/BRNT MILL RD over DRY WASH
Structure number:PUCO15.55-211BR
Location:10.6 MI ESE OF BEULAH
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:29.5 ft. [9.0 m]
Total length:31.5 ft. [9.6 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:32.5 ft. [9.9 m]
Owner:County Highway Agency [02]
Year built:1990
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2014

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:132 [as of 2014]
Truck traffic:2% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:78.4 tons [71.3 metric tons]
Inventory rating:47.0 tons [42.7 metric tons]
Sufficiency rating:97.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201497.7FairSatisfactorySatisfactoryGood-132
November 201297.7FairSatisfactorySatisfactoryGood-162
November 201098.7FairSatisfactorySatisfactoryGood-162
November 200898.8FairSatisfactorySatisfactoryGood-82
November 200698.8FairSatisfactoryGoodGood-82
August 200498.8GoodGoodGoodGood-82
January 200399.8GoodGoodGoodGood-82
February 200099.8GoodGoodGoodGood-87
March 199999.8GoodGoodGoodGood-87
March 199899.8GoodGoodGoodGood-87
October 199699.8GoodVery GoodGoodGood-75
May 199499.8GoodVery GoodGoodGood-75
July 199299.8GoodVery GoodGoodGood-75
November 199099.9GoodVery GoodGoodGood-70

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.2210197240
Steel Protective Coatingsq. ft.221221000
Deck
Reinforced Concrete Decksq. ft.2,0482,048000
Substructure
Reinforced Concrete Abutmentlinear ft.6565000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.6363000