Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:MONROE STREET, NE over CSX RAILROAD
Structure number:0568
Location:MONROE ST OVER CSX RR
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Minor Arterial (Urban) [16]
Length of largest span:59.1 ft. [18.0 m]
Total length:126.0 ft. [38.4 m]
Roadway width between curbs:49.9 ft. [15.2 m]
Deck width edge-to-edge:65.9 ft. [20.1 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1931
Year reconstructed:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:14,900 [as of 2007]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Superior to present desirable criteria [9]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:46.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairFairFairFair1490046.9
March 2016FairFairFairFair1490064.7
February 2015FairFairFairFair1490064.7
March 2013FairFairFairFair1490065.8
January 2011FairSatisfactoryFairFair1490066.8
August 2008FairSatisfactorySatisfactorySatisfactory1490078.2
November 2003FairSatisfactorySatisfactoryFair1500066.8
October 1999FairFairSatisfactoryGood1500077.1
December 1996FairSatisfactoryGoodGood1500078.2
April 1993FairSatisfactoryGoodGood1500080.6
December 1990FairSatisfactoryGoodGood1500080.6

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.1,7081,3741681660
Prestressed Concrete Girder/Beamlinear ft.244244000
Deck
Prestressed Concrete Top Flangesq. ft.8,26308,1501130
Wearing Surfacessq. ft.6,00006,00000
Substructure
Reinforced Concrete Columneach82330
Reinforced Concrete Pier Walllinear ft.128804800
Reinforced Concrete Abutmentlinear ft.1405055350
Reinforced Concrete Pier Caplinear ft.1363655450
Joints
Compression Jointlinear ft.396039600
Bearings
Movable Bearingeach4848000
Fixed Bearingeach4847100
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.244244000
Reinforced Concrete Bridge Raillinear ft.244237250
Concrete Protective Coatingsq. ft.820081406