Share:

SOUTHEAST FRWY over PB&W R.R.& VIRGI

Map

Coordinates:
+38.88144, -77.00843
38°52'53" N, 77°00'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SOUTHEAST FRWY over PB&W R.R.& VIRGI
Structure number:1109
Location:SE FRWY OVER VIRGINIA AVE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:145.0 ft. [44.2 m]
Total length:1458.1 ft. [444.4 m]
Roadway width between curbs:122.1 ft. [37.2 m]
Deck width edge-to-edge:127.6 ft. [38.9 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:1964
Year reconstructed:1991
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:12
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:95,800 [as of 2007]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:70.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016FairGoodSatisfactoryFair9580070.0
July 2014FairSatisfactoryGoodFair9580070.0
August 2012FairGoodSatisfactoryFair9580070.0
September 2010FairGoodSatisfactoryFair9580070.0
April 2008FairGoodGoodFair9580070.0
January 2006FairGoodGoodSatisfactory10300081.0
May 2004FairGoodVery GoodSatisfactory10300081.0
February 1998FairGoodVery GoodSatisfactory10300081.0
November 1995GoodVery GoodGoodGood10300081.0
September 1992GoodExcellentVery GoodVery Good10300084.0
July 1988GoodExcellentVery GoodVery Good10300084.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.26,11823,6732,0953500
Steel Protective Coatingsq. ft.394,267335,12643,36914,785987
Deck
Reinforced Concrete Decksq. ft.185,895185,8572360
Superstructure
Steel Floor Beamlinear ft.2,7051,4277665120
Steel Protective Coatingsq. ft.394,267318,37058,69915,7851,413
Steel Pin or Pin & Hangar Assemblyeach55441100
Steel Protective Coatingsq. ft.4403637052
Substructure
Reinforced Concrete Columneach411114151
Concrete Protective Coatingsq. ft.19,55717,49901,080978
Reinforced Concrete Abutmentlinear ft.1441132740
Reinforced Concrete Pier Caplinear ft.17835126170
Joints
Strip Seal Jointlinear ft.1,59101,59100
Compression Jointlinear ft.554055400
Assembly with Sealeach4949000
Bearings
Movable Bearingeach5504780
Steel Protective Coatingsq. ft.393732406020
Fixed Bearingeach6005730
Steel Protective Coatingsq. ft.393732406020
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4,3744,2868620
Concrete Protective Coatingsq. ft.34,25013,7003,4253,42513,700