Share:

I-695 SE FREEWAY over 6TH STREET, S.E.

Map

Coordinates:
+38.87970, -76.99892
38°52'47" N, 76°59'56" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-695 SE FREEWAY over 6TH STREET, S.E.
Structure number:1112
Location:SE FREEWAY AT 6TH ST SE
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:74.2 ft. [22.6 m]
Total length:81.0 ft. [24.7 m]
Roadway width between curbs:126.6 ft. [38.6 m]
Deck width edge-to-edge:128.9 ft. [39.3 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:28°
Owner:State Highway Agency [01]
Year built:1968
Year reconstructed:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:95,800 [as of 2007]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:89.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,900,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2016FairGoodGoodSatisfactory9580089.0
September 2014FairGoodGoodSatisfactory9580089.0
September 2012FairSatisfactorySatisfactoryGood9580089.0
September 2010FairSatisfactorySatisfactoryGood9580089.0
September 2008GoodGoodVery GoodGood9580089.0
August 2006GoodGoodVery GoodGood10300088.3
July 2004GoodVery GoodVery GoodVery Good10300088.3
August 2002GoodExcellentVery GoodVery Good10300088.3
August 1997FairGoodFairFair10300072.9
August 1995FairSatisfactoryFairFair10300075.1
November 1992FairSatisfactoryFairFair10300075.1
September 1990FairSatisfactoryFairFair10300075.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,3361,11422200
Steel Protective Coatingsq. ft.11,80111,57802230
Deck
Reinforced Concrete Decksq. ft.10,45710,16529200
Substructure
Reinforced Concrete Abutmentlinear ft.29419763340
Concrete Protective Coatingsq. ft.7,5076,75700750
Joints
Pourable Jointlinear ft.5885780010
Compression Jointlinear ft.37926533081
Bearings
Elastomeric Bearingeach3633300
Steel Protective Coatingsq. ft.6161000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.324323100
Concrete Protective Coatingsq. ft.1,7341,63400100