SOUTHEAST FWY over 8TH STREET
Map
Coordinates:
+38.87891, -76.9968938°52'44" N, 76°59'49" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SOUTHEAST FWY over 8TH STREET |
Structure number: | 1401 |
Location: | SE FRWY OVER 8TH ST |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 80.7 ft. [24.6 m] |
Total length: | 368.1 ft. [112.2 m] |
Roadway width between curbs: | 162.1 ft. [49.4 m] |
Deck width edge-to-edge: | 167.3 ft. [51.0 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 15° |
Owner: | State Highway Agency [01] |
Year built: | 1970 |
Year reconstructed: | 2002 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 114,500 [as of 2007] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 87.3 |
Estimated cost of work: | $1,500,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 114500 | 87.3 |
April 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 114500 | 87.3 |
February 2013 | Fair | Good | Good | Satisfactory | 114500 | 86.1 |
February 2011 | Fair | Satisfactory | Fair | Satisfactory | 114500 | 73.5 |
October 2008 | Good | Good | Good | Good | 114500 | 86.1 |
October 2006 | Good | Good | Good | Good | 103000 | 87.2 |
September 2004 | Good | Very Good | Very Good | Very Good | 103000 | 87.2 |
August 2002 | Good | Excellent | Very Good | Very Good | 103000 | 87.2 |
March 1998 | Fair | Satisfactory | Fair | Satisfactory | 103000 | 72.8 |
January 1996 | Fair | Satisfactory | Fair | Satisfactory | 103000 | 74.0 |
May 1993 | Fair | Satisfactory | Satisfactory | Satisfactory | 103000 | 86.2 |
January 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 103000 | 86.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 9,954 | 9,373 | 0 | 581 | 0 |
Steel Protective Coating | sq. ft. | 59,724 | 59,127 | 0 | 0 | 597 |
Deck |
Reinforced Concrete Deck | sq. ft. | 61,566 | 49,795 | 11,767 | 4 | 0 |
Substructure |
Reinforced Concrete Column | each | 44 | 29 | 10 | 5 | 0 |
Concrete Protective Coating | sq. ft. | 3,648 | 3,283 | 365 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 195 | 158 | 26 | 11 | 0 |
Concrete Protective Coating | sq. ft. | 3,900 | 3,900 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 987 | 831 | 134 | 22 | 0 |
Concrete Protective Coating | sq. ft. | 11,450 | 10,305 | 1,145 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 542 | 0 | 0 | 542 | 0 |
Pourable Joint | linear ft. | 195 | 0 | 195 | 0 | 0 |
Compression Joint | linear ft. | 597 | 97 | 500 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 230 | 230 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,454 | 1,444 | 10 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 5,888 | 4,588 | 588 | 419 | 293 |