Share:

I-275 over SR-582/FOWLER AVENUE

Map

Coordinates:
+28.05444, -82.45444
28°03'16" N, 82°27'16" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-275 over SR-582/FOWLER AVENUE
Structure number:100231
Location:1.5MI NORTH OF SR-580
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:74.2 ft. [22.6 m]
Total length:144.0 ft. [43.9 m]
Roadway width between curbs:107.0 ft. [32.6 m]
Deck width edge-to-edge:113.9 ft. [34.7 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Owner:State Highway Agency [01]
Year built:1966
Year reconstructed:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: May 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:143,000 [as of 2016]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Superior to present desirable criteria [9]
Scour condition:Bridge not over waterway. [N]
Operating rating:53.9 tons [49.0 metric tons]
Inventory rating:37.0 tons [33.6 metric tons]
Sufficiency rating:95.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
May 201695.0GoodGoodGoodGood-143000
May 201495.0GoodGoodGoodGood-141000
May 201293.0GoodGoodGoodGood-148500
May 201093.0GoodGoodGoodGood-151500
May 200893.0GoodGoodGoodGood-147500
May 200693.0GoodGoodGoodGood-150000
May 200493.0GoodGoodGoodGood-124500
September 200393.0GoodGoodGoodGood-109500
September 200193.0GoodGoodGoodGood-54000
September 199992.0GoodGoodGoodVery Good-39000
September 199793.0GoodGoodGoodVery Good-48500
September 199591.0GoodGoodGoodVery GoodFO48000
November 199391.0GoodGoodGoodVery GoodFO36788
February 199290.0GoodGoodGoodVery GoodFO34200

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2,3872,3711600
Deck
Reinforced Concrete Decksq. ft.16,41616,416000
Substructure
Reinforced Concrete Abutmentlinear ft.2282052210
Reinforced Concrete Pileeach1615100
Reinforced Concrete Pier Caplinear ft.228225030
Joints
Pourable Jointlinear ft.45635410101
Bearings
Elastomeric Bearingeach94266800
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.432432000