SR618 CROSSTOWN EB over EUCLID AVENUE

Map

Coordinates:
+27.90862, -82.49983
27°54'31" N, 82°29'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR618 CROSSTOWN EB over EUCLID AVENUE
Structure number:100311
Location:1.1MI N OF GANDY BLVD
Purpose:Carries highway overpass over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Tolls:Yes, on toll road [2]
Length of largest span:78.1 ft. [23.8 m]
Total length:213.9 ft. [65.2 m]
Roadway width between curbs:36.4 ft. [11.1 m]
Deck width edge-to-edge:39.0 ft. [11.9 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:30°
Owner:State Toll Authority [31]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: July 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:16,000 [as of 2017]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:97.2

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2017GoodGoodGoodGood1600097.2
July 2015GoodGoodGoodGood1525097.3
July 2013GoodGoodGoodGood1125097.5
July 2011GoodGoodGoodGood1250096.4
July 2009GoodGoodGoodGood1200096.4
August 2007GoodGoodGoodGood700096.7
August 2005GoodGoodGoodGood1300096.4
August 2003GoodGoodGoodGood980096.5
March 2003GoodGoodGoodGood980096.5
March 2001GoodGoodGoodGood1050089.5
March 1999GoodGoodGoodGood1586092.2
March 1997GoodGoodVery GoodGood1586094.5
April 1995GoodGoodVery GoodGood1586089.7
March 1993GoodGoodVery GoodGood1223490.0
March 1991GoodVery GoodVery GoodGood1223490.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,1481,148000
Deck
Reinforced Concrete Decksq. ft.8,34308,34300
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.8989000
Reinforced Concrete Pier Caplinear ft.8989000
Joints
Pourable Jointlinear ft.167161600
Bearings
Elastomeric Bearingeach3232000
Bridge Rail
Other Material Bridge Raillinear ft.4284002530