Share:

SR-676 over DELANEY CREEK

Map

Coordinates:
+27.92272, -82.37275
27°55'22" N, 82°22'22" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR-676 over DELANEY CREEK
Structure number:100813
Location:1.4 MI. WEST OF US-301
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:14.1 ft. [4.3 m]
Total length:58.1 ft. [17.7 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:90.9 ft. [27.7 m]
Owner:State Highway Agency [01]
Year built:2009
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:18,300 [as of 2017]
Truck traffic:12% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:95.5

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
October 2017Good7 out of 101830095.5
October 2015Good7 out of 102200094.8
October 2013Good7 out of 102350094.5
October 2011Good7 out of 101630095.9
October 2009Good8 out of 101830095.5