Share:

SW 22ND STREET over CHALLENGER CANAL

Map

Coordinates:
+26.61111, -81.98556
26°36'40" N, 81°59'08" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SW 22ND STREET over CHALLENGER CANAL
Structure number:125534
Location:0.12 MI E OF SW 7TH PLACE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:13.8 ft. [4.2 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:39.4 ft. [12.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1974
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:220 [as of 2017]
Truck traffic:1% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:83.1

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2017Good7 out of 1022083.1
November 2015Good7 out of 1022083.1
November 2013Good7 out of 1022098.0
November 2011Good7 out of 1022098.0
November 2009Good7 out of 1022098.0
November 2007Good7 out of 1022098.0
November 2005Good7 out of 1022098.0
November 2003Good7 out of 1022098.0
September 2001Good7 out of 1022098.0
September 1999Good7 out of 1022098.0
September 1997Good7 out of 1022098.0
September 1995Good7 out of 1020098.0
September 1993Good7 out of 1020099.0
August 1991Good7 out of 1020098.0