VISCAYA PARKWAY over MEADE CANAL
Map
Coordinates:
+26.63641, -81.9306326°38'11" N, 81°55'50" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | VISCAYA PARKWAY over MEADE CANAL |
Structure number: | 125554 |
Location: | 0.6MI EAST OF DEL PRADO |
Purpose: | Carries highway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 8.9 ft. [2.7 m] |
Total length: | 25.3 ft. [7.7 m] |
Roadway width between curbs: | 56.8 ft. [17.3 m] |
Deck width edge-to-edge: | 65.9 ft. [20.1 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1968 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 14,800 [as of 2017] |
Truck traffic: | 4% of total traffic |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 81.1 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
November 2017 | Good | 7 out of 10 | 14800 | 81.1 |
November 2015 | Good | 7 out of 10 | 14800 | 81.1 |
November 2013 | Good | 7 out of 10 | 14800 | 81.1 |
November 2011 | Good | 7 out of 10 | 14800 | 93.2 |
November 2009 | Good | 7 out of 10 | 14800 | 93.2 |
November 2007 | Good | 7 out of 10 | 14800 | 93.2 |
November 2005 | Fair | 6 out of 10 | 14800 | 93.9 |
November 2003 | Fair | 6 out of 10 | 14800 | 93.9 |
September 2001 | Fair | 6 out of 10 | 14800 | 78.4 |
September 1999 | Fair | 6 out of 10 | 16000 | 94.7 |
September 1997 | Fair | 6 out of 10 | 16000 | 93.7 |
October 1995 | Fair | 6 out of 10 | 14935 | 78.2 |
October 1993 | Fair | 6 out of 10 | 14935 | 93.7 |
September 1991 | Fair | 6 out of 10 | 12000 | 94.2 |