Share:

CAMP GRADE ROAD over STEINHATCHEE RIVER

Map

Coordinates:
+29.84250, -83.30833
29°50'33" N, 83°18'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CAMP GRADE ROAD over STEINHATCHEE RIVER
Structure number:334001
Location:0.2 MI EAST OF SR 51
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:44.9 ft. [13.7 m]
Total length:223.1 ft. [68.0 m]
Roadway width between curbs:11.2 ft. [3.4 m]
Deck width edge-to-edge:12.1 ft. [3.7 m]
Owner:County Highway Agency [02]
Year built:1921
Year reconstructed:1989
Historic significance:Bridge is eligible for the National Register of Historic Places [2]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: April 2016

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:51 [as of 2016]
Deck condition:Good [7 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:5.5 tons [5.0 metric tons]
Inventory rating:4.2 tons [3.8 metric tons]
Sufficiency rating:18.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,323,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
April 201618.9PoorGoodPoorFairSD51
April 201418.9PoorGoodPoorFairSD51
April 201218.9PoorGoodPoorFairSD51
April 201017.8PoorFairPoorFairSD51
April 200817.8PoorFairPoorFairSD51
April 200617.8PoorFairPoorFairSD51
April 200417.8PoorFairPoorFairSD51
April 200218.8PoorSatisfactoryPoorFairSD51
April 200017.7PoorFairPoorFairSD51
December 199819.8PoorFairSeriousFairSD51
November 199819.8PoorFairSeriousFairSD51
April 199617.7PoorFairSeriousFair-51
August 199420.9PoorSatisfactoryPoorSatisfactory-51
August 199217.7PoorGoodPoorGood-51
September 199017.7FairGoodFairGood-51