US 319 SR 377 over Ochlockonee River
Map
Coordinates:
+29.98802, -84.5021729°59'17" N, 84°30'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 319 SR 377 over Ochlockonee River |
Structure number: | 490028 |
Location: | 5.4 Mi North of US98/SR30 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 57.4 ft. [17.5 m] |
Total length: | 862.6 ft. [262.9 m] |
Roadway width between curbs: | 43.6 ft. [13.3 m] |
Deck width edge-to-edge: | 46.3 ft. [14.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1977 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 15 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: December 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,000 [as of 2016] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 99.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 2000 | 99.4 |
January 2017 | Fair | Good | Satisfactory | Satisfactory | 1750 | 99.5 |
January 2015 | Fair | Good | Satisfactory | Satisfactory | 1600 | 99.6 |
January 2013 | Fair | Good | Good | Satisfactory | 1600 | 99.6 |
January 2011 | Fair | Good | Good | Satisfactory | 1600 | 99.6 |
January 2009 | Fair | Good | Good | Satisfactory | 1800 | 99.5 |
February 2007 | Fair | Good | Good | Satisfactory | 1500 | 99.6 |
March 2005 | Fair | Good | Good | Satisfactory | 2000 | 99.4 |
April 2003 | Fair | Good | Good | Satisfactory | 1850 | 99.5 |
May 2001 | Fair | Good | Good | Satisfactory | 1200 | 99.6 |
June 1999 | Fair | Good | Good | Satisfactory | 1650 | 99.5 |
July 1997 | Fair | Good | Good | Satisfactory | 1250 | 96.3 |
August 1995 | Fair | Good | Good | Satisfactory | 1500 | 96.0 |
August 1993 | Fair | Good | Good | Satisfactory | 1150 | 96.4 |
July 1991 | Fair | Good | Good | Satisfactory | 1473 | 96.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 4,314 | 4,310 | 4 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 39,934 | 0 | 3,993 | 35,941 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 92 | 84 | 8 | 0 | 0 |
Prestressed Concrete Pile | each | 90 | 0 | 0 | 0 | 90 |
Reinforced Concrete Pier Cap | linear ft. | 646 | 568 | 78 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 132 | 83 | 40 | 9 | 0 |
Bearings |
Elastomeric Bearing | each | 150 | 150 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,726 | 1,606 | 120 | 0 | 0 |