Share:

SR-10A EB SVC. RD. over MILL CREEK

Map

Coordinates:
+30.32722, -81.58194
30°19'38" N, 81°34'55" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:SR-10A EB SVC. RD. over MILL CREEK
Structure number:720148
Location:SR-10A SVC.RD./ MILL CRK.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:30.8 ft. [9.4 m]
Total length:526.9 ft. [160.6 m]
Roadway width between curbs:29.5 ft. [9.0 m]
Deck width edge-to-edge:30.5 ft. [9.3 m]
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:17
Main spans material:Prestressed concrete [5]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,001 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:59.8 tons [54.4 metric tons]
Inventory rating:35.9 tons [32.6 metric tons]
Sufficiency rating:92.9
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$1,192,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201592.9FairGoodGoodSatisfactory-1001
December 201397.9GoodGoodGoodGood-701
December 201197.9GoodGoodGoodGood-701
December 200997.9GoodGoodGoodGood-701
December 200790.9GoodGoodGoodGood-701
December 200590.9GoodGoodGoodGood-651
December 200390.9GoodGoodGoodGood-651
January 200278.5GoodGoodGoodGoodFO25000
February 200078.6GoodGoodVery GoodGoodFO23500
March 199877.4GoodGoodVery GoodGoodFO10001
March 199676.8GoodGoodVery GoodGoodFO10001
March 199477.0GoodGoodVery GoodGoodFO10001
April 199275.9Good-Very GoodGoodFO21914
April 199077.3Good-Very GoodGoodFO7001