SR-13 NB (ACOSTA) over ST. JOHNS RIVER
Map
Coordinates:
+30.32194, -81.6641730°19'19" N, 81°39'51" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR-13 NB (ACOSTA) over ST. JOHNS RIVER |
Structure number: | 720571 |
Location: | SR-13 NB/ ST. JOHNS RIVER |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 630.0 ft. [192.0 m] |
Total length: | 1645.1 ft. [501.4 m] |
Roadway width between curbs: | 55.8 ft. [17.0 m] |
Deck width edge-to-edge: | 75.5 ft. [23.0 m] |
Vertical clearance above deck: | 17.1 ft. [5.2 m] |
Vertical clearance below bridge: | 74.8 ft. [22.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Segmental box girder [21] |
Deck type: | Other [9] |
Latest Available Inspection: January 2016
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 15,250 [as of 2014] |
Truck traffic: | 1% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place but in a deteriorated condition [3] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Operating rating: | 71.8 tons [65.3 metric tons] |
Inventory rating: | 42.9 tons [39.0 metric tons] |
Sufficiency rating: | 94.2 |
Previous Inspections
Date | Suff. Rating | Condition | Deck | Superstructure | Substructure | SD/FO | ADT |
---|
January 2016 | 94.2 | Fair | Good | Satisfactory | Good | - | 15250 |
January 2014 | 94.3 | Fair | Good | Satisfactory | Good | - | 14250 |
January 2012 | 94.3 | Fair | Good | Satisfactory | Good | - | 14250 |
January 2010 | 99.3 | Fair | Good | Satisfactory | Good | - | 14500 |
January 2008 | 99.2 | Fair | Good | Satisfactory | Good | - | 17000 |
January 2006 | 99.2 | Fair | Good | Satisfactory | Good | - | 16250 |
January 2004 | 99.3 | Good | Good | Good | Good | - | 16000 |
February 2002 | 99.0 | Good | Good | Good | Good | - | 21000 |
February 2000 | 98.9 | Good | Good | Good | Good | - | 23000 |
February 1998 | 98.9 | Good | Good | Good | Good | - | 23000 |
February 1996 | 98.8 | Good | Good | Good | Good | - | 13000 |
February 1994 | 95.5 | Good | Very Good | Good | Good | - | 30001 |