US-441 SR-15 over SR-76 & St. Lucie Canal
Map
Coordinates:
+26.98533, -80.6170226°59'07" N, 80°37'01" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-441 SR-15 over SR-76 & St. Lucie Canal |
Structure number: | 890103 |
Location: | US-441 and SR-76 |
Purpose: | Carries highway over highway and waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 129.9 ft. [39.6 m] |
Total length: | 2460.1 ft. [749.8 m] |
Roadway width between curbs: | 44.0 ft. [13.4 m] |
Deck width edge-to-edge: | 46.6 ft. [14.2 m] |
Vertical clearance below bridge: | 52.5 ft. [16.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1983 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 25 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: January 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,500 [as of 2015] |
Truck traffic: | 32% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 97.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
January 2017 | Good | Good | Good | Good | 2500 | 97.5 |
January 2015 | Good | Good | Good | Good | 2300 | 97.7 |
January 2013 | Good | Good | Good | Good | 2500 | 96.8 |
January 2011 | Good | Good | Good | Good | 3000 | 96.2 |
January 2009 | Good | Good | Good | Good | 2800 | 96.9 |
January 2007 | Good | Good | Good | Good | 3400 | 93.1 |
February 2005 | Good | Good | Good | Good | 4100 | 91.7 |
February 2003 | Good | Good | Good | Good | 3800 | 86.8 |
February 2001 | Good | Good | Good | Very Good | 3600 | 87.3 |
February 1999 | Good | Good | Good | Very Good | 3300 | 85.9 |
March 1997 | Good | Good | Good | Very Good | 2600 | 87.4 |
February 1995 | Good | Good | Good | Very Good | 3500 | 85.4 |
February 1993 | Good | Good | Good | Very Good | 1526 | 89.7 |
December 1990 | Good | Good | Good | Very Good | 1906 | 88.9 |