Share:

GA SR 37-ALA SR 10 over CHATTAHOOCHEE RIVER

Map

Coordinates:
+31.60425, -85.05604
31°36'15" N, 85°03'22" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:GA SR 37-ALA SR 10 over CHATTAHOOCHEE RIVER
Structure number:000000006100020
Location:AT GA & ALA STATE LINE
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:220.2 ft. [67.1 m]
Total length:824.2 ft. [251.2 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:50.2 ft. [15.3 m]
Vertical clearance below bridge:65.6 ft. [20.0 m]
Owner:State Highway Agency [01]
Year built:1972
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:6
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,830 [as of 2012]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:In place and functioning [2]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:88.7
Estimated cost of work:$4,829,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairSatisfactoryGoodSatisfactory183088.7
May 2015FairSatisfactoryGoodSatisfactory183088.7
May 2013FairSatisfactoryGoodSatisfactory183088.7
May 2011FairSatisfactoryGoodSatisfactory210088.5
May 2009FairSatisfactoryGoodSatisfactory217088.2
May 2007FairSatisfactoryGoodSatisfactory217088.2
May 2005FairSatisfactoryGoodSatisfactory238087.3
May 2003FairSatisfactoryGoodSatisfactory210088.5
May 2001FairSatisfactoryGoodSatisfactory240087.2
July 1999FairSatisfactoryGoodSatisfactory240087.2
June 1997FairSatisfactoryGoodSatisfactory240085.2
April 1995FairSatisfactoryGoodSatisfactory220086.0
April 1993FairSatisfactoryGoodSatisfactory192087.2
May 1991FairSatisfactoryGoodGood192087.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.6,0556,055000
Steel Protective Coatingsq. ft.56,29645,03611,26000
Deck
Reinforced Concrete Decksq. ft.41,44541,445000
Substructure
Reinforced Concrete Columneach105140
Reinforced Concrete Abutmentlinear ft.1068115100
Reinforced Concrete Pile Cap/Footinglinear ft.7600760
Reinforced Concrete Pier Caplinear ft.2652501500
Joints
Pourable Jointlinear ft.240240000
Assembly without Seal Jointlinear ft.9696000
Bearings
Movable Bearingeach2727000
Steel Protective Coatingsq. ft.2702700
Fixed Bearingeach2525000
Steel Protective Coatingsq. ft.2502230
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.1,6481,648000