SR 53 over SHOAL CREEK
Map
Coordinates:
+34.42101, -84.1466634°25'16" N, 84°08'48" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 53 over SHOAL CREEK |
Structure number: | 000000008500100 |
Location: | 1.6 MI W OF DAWSONVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 77.1 ft. [23.5 m] |
Total length: | 231.0 ft. [70.4 m] |
Roadway width between curbs: | 46.9 ft. [14.3 m] |
Deck width edge-to-edge: | 50.5 ft. [15.4 m] |
Skew angle: | 45° |
Owner: | State Highway Agency [01] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,080 [as of 2012] |
Truck traffic: | 1% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 89.5 |
Estimated cost of work: | $1,354,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Fair | Satisfactory | Satisfactory | 6080 | 89.5 |
July 2017 | Fair | Fair | Satisfactory | Satisfactory | 6080 | 89.5 |
June 2015 | Fair | Fair | Satisfactory | Satisfactory | 6080 | 89.5 |
June 2013 | Fair | Fair | Satisfactory | Satisfactory | 6080 | 89.5 |
July 2011 | Fair | Fair | Satisfactory | Satisfactory | 4510 | 90.1 |
July 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 5760 | 90.7 |
June 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 5760 | 90.7 |
June 2005 | Fair | Satisfactory | Good | Good | 6170 | 90.5 |
July 2003 | Fair | Satisfactory | Good | Good | 6000 | 90.6 |
July 2001 | Fair | Satisfactory | Good | Good | 4400 | 95.4 |
October 1999 | Fair | Satisfactory | Good | Good | 4400 | 95.3 |
August 1997 | Fair | Satisfactory | Good | Good | 4400 | 93.3 |
June 1995 | Fair | Satisfactory | Very Good | Good | 4190 | 94.4 |
June 1993 | Good | Good | Very Good | Good | 4190 | 94.4 |
June 1991 | Good | Good | Very Good | Good | 4190 | 94.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,386 | 1,386 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 13,707 | 13,707 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 11,643 | 4,902 | 2,000 | 4,741 | 0 |
Substructure |
Reinforced Concrete Column | each | 6 | 6 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 100 | 100 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 100 | 100 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 141 | 0 | 0 | 141 | 0 |
Bearings |
Movable Bearing | each | 18 | 18 | 0 | 0 | 0 |
Fixed Bearing | each | 18 | 18 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 462 | 462 | 0 | 0 | 0 |