SR 136 over CHESTATEE RIVER
Map
Coordinates:
+34.39819, -83.9757534°23'53" N, 83°58'33" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 136 over CHESTATEE RIVER |
Structure number: | 000000008500200 |
Location: | 8.3 MI SE OF DAWSONVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 91.9 ft. [28.0 m] |
Total length: | 442.0 ft. [134.7 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 26.6 ft. [8.1 m] |
Owner: | State Highway Agency [01] |
Year built: | 1956 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 6 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 3,690 [as of 2012] |
Truck traffic: | 1% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 59.2 |
Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
Estimated cost of work: | $2,590,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Fair | Fair | Fair | 3690 | 59.2 |
June 2017 | Fair | Fair | Fair | Fair | 3690 | 59.2 |
June 2015 | Fair | Fair | Fair | Fair | 3690 | 59.2 |
June 2013 | Fair | Fair | Fair | Satisfactory | 3690 | 59.2 |
June 2011 | Fair | Fair | Fair | Satisfactory | 3400 | 59.7 |
August 2009 | Fair | Fair | Satisfactory | Satisfactory | 3100 | 72.3 |
June 2007 | Fair | Fair | Satisfactory | Satisfactory | 3100 | 10.7 |
June 2005 | Fair | Fair | Satisfactory | Satisfactory | 3100 | 10.7 |
June 2003 | Fair | Fair | Good | Good | 3100 | 72.3 |
August 2001 | Fair | Fair | Good | Good | 2600 | 73.0 |
November 1999 | Fair | Fair | Good | Good | 2000 | 73.9 |
August 1997 | Fair | Fair | Good | Good | 1910 | 74.1 |
June 1995 | Fair | Fair | Good | Good | 1910 | 74.0 |
June 1993 | Fair | Fair | Good | Good | 1910 | 74.0 |
June 1991 | Fair | Fair | Good | Good | 1910 | 60.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,768 | 276 | 1,472 | 20 | 0 |
Steel Protective Coating | sq. ft. | 16,216 | 16,096 | 120 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 11,800 | 11,680 | 0 | 120 | 0 |
Substructure |
Reinforced Concrete Column | each | 5 | 0 | 5 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 54 | 47 | 7 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 17 | 0 | 17 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 125 | 0 | 125 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 110 | 85 | 25 | 0 | 0 |
Assembly without Seal Joint | linear ft. | 22 | 22 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 32 | 8 | 24 | 0 | 0 |
Steel Protective Coating | sq. ft. | 8 | 4 | 4 | 0 | 0 |
Fixed Bearing | each | 8 | 0 | 8 | 0 | 0 |
Steel Protective Coating | sq. ft. | 8 | 4 | 4 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 884 | 884 | 0 | 0 | 0 |