Share:

SR 154 SB Ramp TO over SR 154 Ramp

Map

Coordinates:
+33.79962, -84.48837
33°47'59" N, 84°29'18" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 154 SB Ramp TO over SR 154 Ramp
Structure number:000000012101050
Location:IN WEST ATLANTA
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:60.0 ft. [18.3 m]
Total length:191.9 ft. [58.5 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:26.2 ft. [8.0 m]
Vertical clearance below bridge:16.7 ft. [5.1 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,640 [as of 2012]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:45.5 tons [41.4 metric tons]
Inventory rating:27.7 tons [25.2 metric tons]
Sufficiency rating:87.5

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201587.5FairFairGoodGood-4640
March 201387.5FairFairGoodGood-4640
March 201188.6GoodGoodGoodGood-1900
April 200988.6GoodGoodGoodGood-1900
April 200788.6GoodGoodGoodGood-1990
April 200595.0GoodGoodGoodGood--
March 200394.8GoodGoodGoodGood-5250
March 200195.0GoodGoodVery GoodGood-1000
March 199994.7GoodGoodGoodGood-5250
September 199694.7GoodGoodGoodGood-5250
October 199495.6GoodGoodGoodGood-5250
August 199295.6FairGoodGoodSatisfactory-5250
August 199095.6FairGoodGoodSatisfactory-5250

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.768768000
Steel Protective Coatingsq. ft.5,66005,596640
Deck
Reinforced Concrete Decksq. ft.5,06904,995740
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.5252000
Reinforced Concrete Pier Caplinear ft.7878000
Joints
Pourable Jointlinear ft.1302601040
Bearings
Movable Bearingeach1616000
Steel Protective Coatingsq. ft.1600160
Fixed Bearingeach1616000
Steel Protective Coatingsq. ft.1600160
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.384384000