Share:

I-75 over M9184 ED'WD- M9150 AUBU'

Map

Coordinates:
+33.75441, -84.37831
33°45'16" N, 84°22'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-75 over M9184 ED'WD- M9150 AUBU'
Structure number:000000012106620
Location:IN ATLANTA
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:121.1 ft. [36.9 m]
Total length:535.1 ft. [163.1 m]
Roadway width between curbs:218.2 ft. [66.5 m]
Deck width edge-to-edge:225.1 ft. [68.6 m]
Vertical clearance below bridge:17.1 ft. [5.2 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:5
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:312,590 [as of 2012]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:28.7 tons [26.1 metric tons]
Sufficiency rating:74.9
Recommended work:Widening of existing bridge with deck rehabilitation or replacement. [34]
Estimated cost of work:$13,397,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
June 201574.9FairGoodGoodSatisfactory-312590
July 201374.9FairGoodGoodSatisfactory-312590
June 201163.9FairGoodGoodFair-288120
October 200963.9FairGoodVery GoodFair-288120
February 200869.0FairGoodVery GoodFair-288120
August 200580.0GoodGoodVery GoodGood-349450
August 200380.0GoodGoodVery GoodGood-288200
September 200180.0GoodGoodVery GoodGood-415300
June 199980.0GoodGoodVery GoodGood-415300
June 199680.0GoodGoodVery GoodVery Good-290800
July 199480.0GoodGoodVery GoodVery Good-260800
March 199480.0GoodGoodVery GoodVery Good-242300
November 199180.0GoodGoodVery GoodVery Good-156007

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.21,31121,310100
Deck
Reinforced Concrete Decksq. ft.120,375120,375000
Substructure
Reinforced Concrete Columneach4848000
Reinforced Concrete Abutmentlinear ft.450450000
Reinforced Concrete Pier Caplinear ft.9008703000
Joints
Pourable Jointlinear ft.900900000
Compression Jointlinear ft.450004500
Bearings
Elastomeric Bearingeach398398000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,0701,070000