Share:

EDWARDS ROAD over CHOKEELAGEE CREEK

Map

Coordinates:
+31.88346, -84.31709
31°53'00" N, 84°19'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:EDWARDS ROAD over CHOKEELAGEE CREEK
Structure number:000000017750060
Location:4 MI SW OF SMITHVILLE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:20.0 ft. [6.1 m]
Total length:80.1 ft. [24.4 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:25.3 ft. [7.7 m]
Owner:County Highway Agency [02]
Year built:1974
Year reconstructed:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Channel beam [22]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10 [as of 2012]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Sufficiency rating:82.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$469,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2018FairGoodGoodFair1082.8
February 2016FairGoodGoodSatisfactory1093.8
February 2014FairGoodGoodSatisfactory1093.8
February 2012FairGoodGoodSatisfactory10488.3
February 2010FairGoodGoodSatisfactory14088.2
February 2008GoodGoodGoodGood14088.2
February 2006GoodGoodGoodGood7093.8
February 2004GoodGoodGoodGood10083.0
February 2002GoodGoodGoodGood10082.9
February 2000GoodVery GoodVery GoodGood23078.9
March 1998GoodVery GoodVery GoodGood23078.9
October 1995GoodVery GoodVery GoodGood23078.4
January 1994FairVery GoodVery GoodFair23054.9
January 1992FairVery GoodVery GoodFair23061.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.640640000
Deck
Reinforced Concrete Top Flangesq. ft.2,0162,016000
Substructure
Reinforced Concrete Abutmentlinear ft.6262000
Steel Pileeach120930
Steel Protective Coatingsq. ft.8920400286206
Reinforced Concrete Pier Caplinear ft.7575000
Joints
Pourable Jointlinear ft.120120000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.160160000